You can manually configure the minimum fan speed of the m1000e so that the chassis maintains a lower operating temperature.
SSH The CMC with the cmc ip address and port 22. User will be root and calvin unless changed.
Then run:
racadm config -g cfgThermal -o cfgThermalMFSPercent 75
This will set the minimum fan speed to 75%. You can set it from 0-100%. Obviously 0% is more like 35% but you won’t be able to tell.
You can view the requested fan speed by the servers in the chassis by running:
racadm getfanreqinfo
Example:
[Server Module Fan Request Table]
<Slot#> <Server Name> <Blade Type> <Power State> <Presence> <Fan Request%>
1 s2086.corp PowerEdgeM610 ON Present 48
2 s2087.corp PowerEdgeM610 ON Present 48
3 s2088.corp PowerEdgeM610 ON Present 48
[Switch Module Fan Request Table]
<IO> <Name> <Type> <Presence> <Fan Request%>
Switch-1 MXL 10/40GbE 10 GbE KR Present 30
Switch-2 MXL 10/40GbE 10 GbE KR Present 30
Switch-3 N/A None Not Present N/A
Switch-4 N/A None Not Present N/A
Switch-5 N/A None Not Present N/A
Switch-6 N/A None Not Present N/A
[Minimum Fan Speed %]
65
thank you very much. this command “racadm getfanreqinfo” solved my problem. My chassis was making so much noise and i had no idea which blade was the culprit. interestingly the machine with 99% fan-request is not even close to hot! Anyway thanks for the help.
Hello, How can you regulate the fan request of the blade? Thank you very much.
You cant.